D-Glucuronic acid and D-Galacturonic acid Assay Kit

Cat.No. :
Kit-2058
Product Overview :
Enzymatic method for the determination of D-glucuronic acid and D-galacturonic. Based on the spectrophotometric measurement of NADH produced though the reaction, after addition of uronate dehydrogenase (UDH).
Size :
100 tests
Description :
D-Glucuronic acid and D-glucuronic acid are naturally occurring hexuronic acids present in glycosaminoglucans, glucuronid conjugates in plant polysaccharides and in mammals. Both D-glucuronic acid and D-glucuronic acid are major components of plant cell wall polysaccharides, being D-glucuronic a component of arabinoxylan and Dgalacturonic the major component of pectin. In mammals, Dglucuronic acid occur as a component of glycosaminoglucans, such as hyaluronan, heparin and chondroitin present in cartilage.
Applications :
This rapid and simple method is used for the determination of D-glucuronic acid and D-galacturonic acid in a variety of matrices. This kit is adequate to D-hexuronic acids (including D-glucuronic acid and D-galacturonic acid) measurement in hydrolysates of plant material and polysaccharides, as well as other materials.
Kit Components :
Solution 1. Buffer (22 mL, pH 8.0) plus sodium azide (0.02% w/v) as a preservative. Stable for 2 years at 4 °C. Solution 2. NAD+ freeze dried powder. Stable for 5 years at -20 °C. Dissolve content in 22 mL of distilled water and divide into appropriately sized aliquots and store in PP tubes at -20 °C between use (stable for 2 years) and keep cool during use. Suspension 3. Uronate dehydrogenase (UDH) in 3.2 M ammonium sulphate (2.2 mL). Stable for 2 years at 4 °C. Swirl bottle before use. Solution 4. D-glucuronic standard solution (5 mL, 0.5 mg/mL). Stable for >2 years at 4 °C. This standard solution can be used when there is some doubt about the method accuracy.
Detection method :
UV method
Compatible Sample Types :
Hydrolysates of plant material and polysaccharides, cell culture medium and fermentation samples as well as other materials.
Features & Benefits :
Simple formatStable reagentsSuitable for manual and micro volume formats
Sensitivity :
Reaction volume: 2.52 mLRange: 5-1500 mg/LDetection limit: 17.4 mg/L