Anti-SARS-CoV-2 Spike RBD Antibody-coupled magnetic beads

Cat.No. : RBD-008M
Product Overview : The biotinylated Anti-SARS-CoV-2 Spike RBD Antibody was conjugated to streptavidin magnetic beads. This pre-coupled magnetic bead product can capture the SARS-CoV-2 S1 protein/SARS-CoV-2 Spike RBD from various assay systems. The beads are in uniform size, narrow size distribution with large surface area and unique surface coating, which can help you get the best performance and highly reproducible results. This Anti-SARS-CoV-2 Spike RBD Antibody coupled magnetic beads will bring great convenience with minimum non-specific binding and developed protocols. This ready-to-use product could greatly save your time and hassle.
  • Specification
  • Gene Information
  • Related Products
Species : SARS-CoV-2
Beads Size : 2mg
Particle size : 2 μm
Beads Surface : hydrophilic
Coupled amount of protein : >300 nmol /mg Beads
Capacity : > 200 nmol S1 or RBD protein / mg beads
Formulation : Lyophilized from 0.22 μm filtered solution in PBS, 0.05% Tween-20, pH7.4, with 10% trehalose
Reconstitution : 2 mL ultrapure water (1mg beads/mL)
Application : This product is intended for immunocapture.
Storage : Upon receipt, please store the Beads at -20ºC for 1 year in lyophilized state. Once the Beads reconstitution, please use it immediately. Do not to freeze thaw the Beads after reconstitution.
Assay Principles : The conjugation was achieved by means of the binding between streptavidin and biotin. Streptavidin (SA) has an extraordinarily high affinity for biotin with a dissociation constant (Kd) on the order of 10-14 mol/L. Thus, the binding of streptavidin and biotin is irreversible. Our Anti-SARS-CoV-2 Spike RBD Antibody-coupled magnetic beads could capture anything binding to Anti-SARS-CoV-2 Spike RBD Antibody, and make the following testing easy, such as immunocapture.
Application Method : a) Reconstitute the Beads following the COA. Wash and re-suspended the beads to a certain concentration by adding your dilution buffer.
b) Add the prepared beads to your samples.
c) Beads can be separated from your samples afterwards using a magnetic plate.