Exosome Isolation and Analysis Kit

Cat.No. : KITG-029
Product Overview : Exosomes are small endosome-derived lipid nanoparticles (50–120 nm) actively secreted by exocytosis by most living cells. Exosome release occurs either constitutively or upon induction, under both normal and pathological conditions, in a dynamic, regulated and functionally relevant manner. Both the amount and molecular composition of released exosomes depend on the state of a parent cell. Exosomes have been isolated from diverse cell lines (hematopoietic cells, tumor lines, primary cultures, and virus infected cells) as well as from biological fluids in particular blood (e.g., serum and plasma from cancer patients) and other body fluids (broncho alveolar lavage fluid, pleural effusions, synovial fluid, urine, amniotic fluid, semen, saliva, etc.). Exosomes have pleiotropic physiological and pathological functions and an emerging role in diverse pathological conditions such as cancer, infectious and neurodegenerative diseases.
  • Specification
  • Gene Information
  • Related Products
  • Download
Species : Human
Description : This kit is a double sandwich enzyme-linked immunoassay for quantitative and qualitative analysis of exosomes. It is a successful platform for exosomes quantification and characterization from small amounts of human biological fluids (plasma, serum, urine, saliva) or cell media. It may be exploited to identify exosomes released by cancer cells in the plasma and urine of tumor patients in various disease conditions. The kit consists of ELISA plates pre-coated with proprietary pan-exosome antibodies enabling specific capture of exosomes from cell culture supernatants. Quantification and characterization of exosomal proteins is subsequently performed using appropriate detection antibodies against exosome associated antigens that can be for either generic or cell/tissue-specific exosomes. The kit contains Lyophilized Exosome Standards for assay calibration. Lyophilized Exosome Standards, characterized for protein content and particle number, allow the quantification of unknown sample by a standard calibration curve.
Form : Colorimetric ELISA Kit (96-well plate)
Applications : Quantitative and qualitative analysis of exosomes from cell culture supernatant and human biological fluids (plasma, serum, urine, saliva). For research use only. Not for use in diagnostic procedures.
Notes : Kit Components: Immunoplate (Transparent): 1 Unit Exosome Standards: 2 × 100 μg (lyophilized) HRP-Conjugate: 1 × 5 μL 1X Sample Buffer: 2 × 10 mL Stop Solution: 1 × 10 mL 25X Washing Buffer: 1 × 25 mL Primary Antibody (mouse anti-human exosome Detection Antibody): 1 × 20 μL Substrate Chromogenic Solutions: 1 × 10 mL Storage and Stability: On receipt, entire assay kit should be stored at 4°C, and used within 24 months. Do not freeze. Reagent Preparation: Before using the kit, bring all the reagents to room temperature (15–30 mins). Washing Buffer: Dilute the 25X Washing Buffer to 1X with deionized water. If crystals are observed, dissolve them by warming up the vial at 37°C before preparing a dilution. Detection Antibody: Dilute to 500-fold in sample buffer. HRP-Conjugated Antibody: Dilute to 5000-fold in sample buffer. Substrate Solution: Ready to use. Stop Solution: Ready to use. Sample Preparation: Cell Culture Medium Sample Preparation: In general, unfractionated samples are analyzed without dilutions (100 μL/well). If the OD values observed are beyond the range of standard curve, dilute the samples using 1X PBS. Prepare samples by 3 centrifugation steps at 4°C. After each step, transfer the supernatant to a new tube and discard the pellet: a. 10 min at 300 g b. 20 min at 1200 g c. 30 min at 10,000 g Concentrate cell supernatant 10–20 fold in spin concentrator. Note: The quantity of exosomes could vary between samples. A larger starting amount of sample should be used if the signal is weak. Standard Preparation: Reconstitution of Exosome Standard: Reconstitute lyophilized standard by adding 100 μL of deionized water to each of the tubes and pipetting the solution up and down 10–15 times, avoiding bubbles. Vortex the reconstituted standard for 60 sec. Briefly centrifuge the tubes containing standards to ensure that the solution is collected at the bottom of the tube. Pipette the solution up and down 10 times, again avoiding bubbles. Briefly centrifuge again. Add 100 μL of 1X PBS to reach a final volume of 200 μL per tube. Note: The remaining reconstituted standard stock solution after use should be aliquoted into polypropylene vials (preferably low binding) and stored at -20°C for up to one month or at -80°C for up to six months. Strictly avoid repeated freeze-and-thaw cycles. Standard Curve Preparation: Standard dilutions are prepared directly in the strips. Please use the exosome stock solution prepared as indicated above to perform six two-fold serial dilutions using 1X PBS. The standard concentrations in the wells will be represented as 50 μg, 25 μg, 12.5 μg, 6.25 μg, 3.125 μg, 1.5625 μg and 0.78125 μg. Serial dilution procedure: a. Add 200 μL of reconstituted exosome solution to wells A1 and A2 (2 wells only). b. Add 100 μL of 1X PBS to wells B1 to H2 (14 wells). c. Transfer 100 μL of A1 into B1 and mix. d. Transfer 100 μL of B1 into C1 and mix. e. Transfer 100 μL of C1 into D1 and mix. f. Transfer 100 μL of D1 into E1 and mix. g. Transfer 100 μL of E1 into F1 and mix. h. Transfer 100 μL of F1 into G1 and mix. i. Discard 100 μL from G1 to result in a final volume of 100 μL. Note: Leave H1 (and H2) as 1X PBS for negative controls. Repeat serial dilution for A2 to H2. Assay Procedure: Exosome Binding: Add 100 μL of prepared samples to wells A3 to H12, adding 1X PBS if required to make the volume up to 100 μL. Seal the plate with parafilm and incubate at room temperature while shaking for 30 min (2–3 rotations per sec). Transfer the plate to 37°C and incubate overnight (12 hr–20 hr) in a humid chamber (for cell culture medium samples). Washing Procedure: Wash the plate by adding 200 μL of Washing Buffer to each well, then discard the plate contents by pouring it out into a sink or waste disposal. Repeat this operation three times with 300 μL/well of Washing Buffer. Do not touch the wells at any time. All subsequent washings should be performed in the same manner. Primary Antibody Binding: Add 100 μL of the diluted mouse anti-human exosome Detection Antibody solution to each well. Seal the plate with parafilm and incubate at room temperature while shaking for 15 min (2–3 rotations per sec). Then incubate for 2 hours at 37°C (for cell culture medium samples). After the incubation, repeat the washing procedure above. HRP-Conjugated Antibody Binding: Add 100 μL of the diluted Streptavidin-HRP antibody solution to each well. Seal the plate with parafilm and incubate at room temperature while shaking for 15 min (2–3 rotations per sec), then incubate for 1 hr at 37°C (for cell culture medium samples). After the incubation, repeat the washing procedure above. Colorimetric Detection: Add 100 μL of Substrate Chromogenic Solution to each well and incubate at room temperature, in the dark, for 5–10 mins. Be careful not to immerse metallic components of a pipette into the substrate solution. Avoid making bubbles and, if formed, remove them gently with a pipette tip. Do not seal the plate. Continue to monitor the plate until a blue color is visible. The intensity of color is proportional to the exosome concentration only within a certain dynamic range. Many plate readers do not deliver accurate results when the OD is above 3. Stop the reaction by adding 100 μL of Stopping Solution to each well. The color will change from blue to yellow. Read the absorbance at 450 nm within 10 minutes. If possible, the absorbance should also be read at 570 nm and the measurement should be subtracted from the measurement of absorbance at 450 nm. Calculations: Exosome standards are provided as assay calibrators and as the positive control. It is important to note that the origin of purified standard exosomes may change the proportion of common exosomal proteins such as CD9. The amounts of proteins on their membrane might differ slightly from the amounts on the sample exosomes. The standard curve is used to determine the amount of exosomes in an unknown sample; this is obtained by plotting the average readings for different standard concentrations against the corresponding amounts of exosomes. Calculate the mean absorbance for each set of duplicate standards, controls and samples. The values of the negative controls (blanks) must be subtracted from all OD values before the results can be interpreted. The regression curve coefficient should be above 0.95. The estimated sample concentration is reliable if within the linear range of the curve, otherwise the samples must be diluted and the test repeated. For diluted samples, multiply the concentrations with the appropriate dilution factor. Precautions: - On receipt, entire assay kit should be stored at 4°C, and used within 24 months. Do not freeze. - Unused strips should be placed back in the foil pouch with the included desiccant pack, resealed and stored at +4°C for up to one month. - The quantity of exosomes could vary between samples. A larger starting amount of sample should be used if the signal is weak. - The intensity of color is proportional to the exosome concentration only within a certain dynamic range. Many plate readers do not deliver accurate results when the OD is above 3. - If possible, the absorbance should also be read at 570 nm and the measurement should be subtracted from the measurement of absorbance at 450 nm. - The remaining reconstituted standard stock solution after use should be aliquoted into polypropylene vials (preferably low binding) and stored at -20°C for up to one month or at -80°C for up to six months. Strictly avoid repeated freeze-and-thaw cycles. Materials Required, Not Supplied: - Single-use and/or pipettes with disposable tips, 2–100 μL - Polypropylene tubes - Pipettes 1 mL and 5 mL for reagent preparation - Deionized water - PBS - Plate shaker - Humidified chamber or incubator at 37°C - Disposable pipetting reservoirs - Microplate reader - ELISA sealing film or parafilm
Storage : Store at 4°C. Do not freeze. Valid for 24 months from receipt.
Shipping : Shipped at ambient temperature.
EC : 1X Sample Buffer, 1X PBS
Storage Buffer : 1X Sample Buffer, 1X PBS
Labeling Efficiency : For research use only. Not for use in diagnostic procedures.

Not For Human Consumption!

Inquiry

  • Reviews (0)
  • Q&As (0)

Customer Reviews

Write a review

Ask a Question for All Products

Required fields are marked with *

My Review for All Products

Required fields are marked with *

0
cart-icon
0
compare icon